my scenario:

i have ds3400 disk system dual controller fibre channel storage equipped 2 controllers each equipped 2 4-gbps fc ports, total of 4 fc ports.

then have 4 servers each equipped 1 ibm 4-gbps fc single-port pci-e hba card.

i'm trying setup windows 2012-r2 hyper-v cluster.

it sufficient connect each server 1 of 4 fc ports of ds3400 or need sort of fc switch obtain fact if 1 storage's controller crash cluster still obtain access storage ?

thank support !

ivano c.



ivano carrara

"what "fc clusters" expecially ?"

a failover cluster uses fibre channel storage.

okay, looking @ configuration, not able configure highly available fc cluster.  apologize. glanced @ configuration first time , did not read details.

"servers each equipped 1 ibm 4-gbps fc single-port pci-e hba card"

each server need 2 hbas each server can connect both fc controllers in storage array.  need configure mpio on each server.

in environment, technically switch not needed because have 4 ports on each of fc controllers in san array, not optimal configuration because each server going use 1 of ports on each controller (when second hba in each server).  means cannot more 4 servers connected array.  makes more sense have two switches in between.  way need 2 connections each switch, total of 2 ports used on storage array.  connect many more 4 nodes storage array connecting them switches.


. : | : . : | : . tim



Windows Server  >  High Availability (Clustering)



Comments

Popular posts from this blog

Error: 0x80073701 when trying to add Print Services Role in Windows 2012 Standard

Disconnecting from a Windows Server 2012 R2 file sharing session on a Windows 7,8,10 machine